Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

S. JAUR VIEUSSAN-LE LAU · Vieussan

S. VALLEE DU JAUR

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.04 (Near the limit)0.2 – 10.001
Total Chlorinemg CL2/l0.09No limit0.018

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC25.4No limit25.4
Hardnessmg CaCO3/l9680 – 45996
Hardness fF9.6No limit9.6
pH7.756.5 – 9.57.75
TurbidityNTU0.54≤ 40.054
ColorColor Units5≤ 155
ConductivityμS / cm273≤ 2,500273
TDSmg/l174.7estimated0 – 1,199174.7
Alkalinitymg CaCO3/l102.5No limit102.5
Bicarbonatemg HCO3/l135Sampled Jan 2025No limit135

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0Sampled Mar 2026≤ 00
eColiUFC/100ml2≤ 00.2
BacteriasNMP/100ml2≤ 00.2
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l10Sampled Jan 2025≤ 500.5
Fluoridemg F/l0.11Sampled Jan 2025≤ 1.50.033
Mercuryμg Hg/l0.01Sampled Jan 2025≤ 10.001
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l0.5≤ 500.15

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l4.5No limit4.5
Calciummg/l31No limit31
Potassiummg/l0.5Sampled Jan 2025No limit0.5
Chloridemg/l15.1≤ 25015.1

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l10Sampled Jan 2025≤ 20010
Arsenicμg/l2Sampled Jan 2025≤ 101
Bariumμg/l10Sampled Jan 2025≤ 1,00010
Ironμg/l10Sampled Jan 2025≤ 20010
Manganeseμg/l10Sampled Jan 2025≤ 5010
Leadμg/lNot reported≤ 10—
Seleniumμg/l2Sampled Jan 2025≤ 102
Sodiummg/l12.5Sampled Jan 2025≤ 20012.5

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled Jan 2025No limit0.005

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Heptachlorug/L0.005Sampled Jan 2025≤ 0.40.005
Total pesticidesug/L0.005Sampled Jan 2025≤ 0.50.005

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled Jan 2025≤ 700.02
Atrazineug/L0.005Sampled Jan 2025≤ 30.005

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
Total PFASug/LNot reported≤ 0.1—
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l13.1No limit13.1

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.