Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

FERRIERE SUR BEAULIEU · Perrusson

CC LOCHES SUD TOURAINE

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.09 (Near the limit)0.2 – 10.002
Total Chlorinemg CL2/l0.1No limit0.02

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC20.5No limit20.5
Hardnessmg CaCO3/l19780 – 459197
Hardness fF19.7No limit19.7
pH7.76.5 – 9.57.7
TurbidityNTU0.61≤ 40.061
ColorColor Units5≤ 155
ConductivityμS / cm426≤ 2,500426
TDSmg/l272.6estimated0 – 1,199272.6
Alkalinitymg CaCO3/l220No limit220

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l5Sampled Jun 2026≤ 500.25
Fluoridemg F/l0.19Sampled Jun 2026≤ 1.50.058
Mercuryμg Hg/l0.015Sampled Jun 2026≤ 10.002
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l0.64≤ 500.19

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l13.5Sampled Jun 2026No limit13.5
Calciummg/l55.1Sampled Jun 2026No limit55.1
Potassiummg/l4.8Sampled Jun 2026No limit4.8
Chloridemg/l17.3≤ 25017.3

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l2Sampled Jun 2026≤ 2002
Antimonyμg/l0.2Sampled Jun 2026≤ 50.2
Arsenicμg/l0.2Sampled Jun 2026≤ 100.1
Bariumμg/l6Sampled Jun 2026≤ 1,0006
Cadmiumμg/l0.01Sampled Jun 2026≤ 50.01
Chromiumμg/l0.5Sampled Jun 2026≤ 500.5
Copperμg/l16.9≤ 2,0000.85
Ironμg/l75≤ 20075
Manganeseμg/l1Sampled Jun 2026≤ 501
Leadμg/l0.7≤ 100.035
Nickelμg/l0.8≤ 200.8
Seleniumμg/l0.2Sampled Jun 2026≤ 100.2
Sodiummg/l20.8Sampled Jun 2026≤ 20020.8

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled Jun 2026No limit0.005
Total Trihalomethanesμg/l0.93Sampled Jun 2026≤ 1000.047

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsμg/l0.55Sampled Jun 2026≤ 600.028

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Heptachlorug/L0.001Sampled Jun 2026≤ 0.40.001
Total pesticidesug/L0Sampled Jun 2026≤ 0.50

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled Jun 2026≤ 700.02
Atrazineug/L0.01Sampled Jun 2026≤ 30.01

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Jun 2026No limit0.001
PFOSug/L0.002Sampled Jun 2026No limit0.002
PFNAug/L0.001Sampled Jun 2026No limit0.001
Total PFASug/L0Sampled Jun 2026≤ 0.10
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l31.1No limit31.1
Uraniumug/L0.1Sampled Jun 2026No limit0.1

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.