Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

SYNDICAT MIXTE DU MARKSTEIN · Mitzach

CALEO

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.240.2 – 10.005
Total Chlorinemg CL2/l0.29No limit0.058

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC13.4No limit13.4
Hardnessmg CaCO3/l28 (Near the limit)80 – 45928
Hardness fF2.8No limit2.8
pH8.36.5 – 9.58.3
TurbidityNTU0.2≤ 40.02
ColorColor Units5Sampled Oct 2025≤ 155
ConductivityμS / cm76≤ 2,50076
TDSmg/l48.6estimated0 – 1,19948.6
Alkalinitymg CaCO3/l29No limit29

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Mercuryμg Hg/lNot reported≤ 1—
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l1.3≤ 500.39

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l1.4No limit1.4
Calciummg/l8.8No limit8.8
Chloridemg/l3.7≤ 2503.7

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Arsenicμg/lNot reported≤ 10—
Cadmiumμg/l0.01Sampled Oct 2025≤ 50.01
Chromiumμg/l0.37Sampled Oct 2025≤ 500.37
Ironμg/l51Sampled Oct 2025≤ 20051
Leadμg/lNot reported≤ 10—

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.002Sampled May 2025No limit0.002
PFOSug/L0.002Sampled May 2025No limit0.002
PFNAug/L0.002Sampled May 2025No limit0.002
Total PFASug/L0.005Sampled May 2025≤ 0.10.001
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.05No limit0.015
Sulfatemg/l2No limit2

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.