STE SEVERE · La Châtre

SIAEP STE SEVERE SUR INDRE

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.220.2 – 10.004
Total Chlorinemg CL2/l0.26No limit0.052

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC22.5No limit22.5
Hardnessmg CaCO3/l10680 – 459106
Hardness fF10.6No limit10.6
pH7.56.5 – 9.57.5
TurbidityNTU0.3≤ 40.03
ColorColor Units5≤ 155
ConductivityμS / cm219Sampled Dec 2025≤ 2,500219
TDSmg/l140.2Sampled Dec 2025estimated0 – 1,199140.2
Alkalinitymg CaCO3/l125No limit125
Bicarbonatemg HCO3/l155Sampled May 2025No limit155

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l5Sampled May 2026≤ 500.25
Fluoridemg F/l0.14Sampled May 2026≤ 1.50.043
Mercuryμg Hg/l0.015Sampled May 2026≤ 10.002
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l11≤ 503.3

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l8.5Sampled May 2026No limit8.5
Calciummg/l25.8Sampled May 2026No limit25.8
Potassiummg/l5.3Sampled May 2026No limit5.3
Chloridemg/l9.68≤ 2509.68

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l8Sampled May 2026≤ 2008
Antimonyμg/l0.2Sampled May 2026≤ 50.2
Arsenicμg/l0.6Sampled May 2026≤ 100.3
Bariumμg/l136Sampled May 2026≤ 1,000136
Cadmiumμg/l0.01Sampled May 2026≤ 50.01
Chromiumμg/l0.5Sampled May 2026≤ 500.5
Copperμg/l56.4≤ 2,0002.82
Ironμg/l6≤ 2006
Manganeseμg/l1Sampled May 2026≤ 501
Leadμg/l1.4≤ 100.07
Nickelμg/l1≤ 201
Sodiummg/l7.8Sampled May 2026≤ 2007.8

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled May 2026No limit0.005
Total Trihalomethanesμg/l3.1Sampled May 2026≤ 1000.16

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsμg/l0.62Sampled May 2026≤ 600.031

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Heptachlorug/L0.001Sampled May 2026≤ 0.40.001
Total pesticidesug/L0.011Sampled May 2026≤ 0.50.011

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled May 2026≤ 700.02
Atrazineug/L0.01Sampled May 2026≤ 30.01

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled May 2026No limit0.001
PFOSug/L0.002Sampled May 2026No limit0.002
PFNAug/L0.001Sampled May 2026No limit0.001
Total PFASug/L0Sampled May 2026≤ 0.10
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l7.34No limit7.34
Uraniumug/L0.2Sampled May 2026No limit0.2

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.