CCAC HERPONT · Courtisols

VEOLIA EAU

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.05 (Near the limit)0.2 – 10.001
Total Chlorinemg CL2/l0.06No limit0.012

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC24No limit24
Hardnessmg CaCO3/l24080 – 459240
Hardness fF24No limit24
pH7.56.5 – 9.57.5
TurbidityNTU0.3≤ 40.03
ColorColor Units5≤ 155
ConductivityμS / cm495≤ 2,500495
TDSmg/l316.8estimated0 – 1,199316.8
Alkalinitymg CaCO3/l181No limit181
Bicarbonatemg HCO3/l221No limit221

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Mercuryμg Hg/lNot reported≤ 1—
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l43.1 (Near the limit)≤ 5012.9

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l0.74No limit0.74
Calciummg/l95No limit95
Chloridemg/l21≤ 25021

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Arsenicμg/lNot reported≤ 10—
Leadμg/lNot reported≤ 10—

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Total pesticidesug/L0.66 (Outside the range)≤ 0.50.66

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Jun 2025No limit0.001
PFOSug/L0.001Sampled Jun 2025No limit0.001
PFNAug/L0.001Sampled Jun 2025No limit0.001
Total PFASug/L0.028Sampled Jun 2025≤ 0.10.003
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.05No limit0.015
Perchlorateug/L1No limit1
Sulfatemg/l7.9No limit7.9

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.