Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

ECRIENNES · Courdemanges

SAUR FRANCE (89)

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.390.2 – 10.008
Total Chlorinemg CL2/l0.42No limit0.084

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC15No limit15
Hardnessmg CaCO3/l30380 – 459303
Hardness fF30.3No limit30.3
pH7.86.5 – 9.57.8
TurbidityNTU0.61≤ 40.061
ColorColor Units5≤ 155
ConductivityμS / cm605≤ 2,500605
TDSmg/l387.2estimated0 – 1,199387.2
Alkalinitymg CaCO3/l300No limit300
Bicarbonatemg HCO3/l366No limit366

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Mercuryμg Hg/lNot reported≤ 1—
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l0.5≤ 500.15

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l24.6No limit24.6
Calciummg/l81No limit81
Chloridemg/l8.3≤ 2508.3

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Arsenicμg/lNot reported≤ 10—
Ironμg/l259 (Outside the range)≤ 200259
Leadμg/lNot reported≤ 10—

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Total pesticidesug/L0.5 (Near the limit)≤ 0.50.5

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Jun 2025No limit0.001
PFOSug/L0.001Sampled Jun 2025No limit0.001
PFNAug/L0.001Sampled Jun 2025No limit0.001
Total PFASug/L0.028Sampled Jun 2025≤ 0.10.003
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.05No limit0.015
Sulfatemg/l29.1No limit29.1

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.