Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

ARGIS BOURG · Conand

SOGEDO LYON

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.220.2 – 10.004
Total Chlorinemg CL2/l0.26No limit0.052

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC16.2No limit16.2
Hardnessmg CaCO3/l17480 – 459174
Hardness fF17.4No limit17.4
pH7.86.5 – 9.57.8
TurbidityNTU0.63≤ 40.063
ColorColor Units5≤ 155
ConductivityμS / cm365≤ 2,500365
TDSmg/l233.6estimated0 – 1,199233.6
Alkalinitymg CaCO3/l170.5No limit170.5

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l10Sampled Jun 2025≤ 500.5
Fluoridemg F/l0.06Sampled Jun 2025≤ 1.50.018
Mercuryμg Hg/l0.01Sampled Jun 2025≤ 10.001
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l6.3≤ 501.89

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l2No limit2
Calciummg/l66.3No limit66.3
Potassiummg/l0.2Sampled Jun 2025No limit0.2
Chloridemg/l1.2≤ 2501.2

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l17Sampled Jun 2025≤ 20017
Arsenicμg/l2Sampled Jun 2025≤ 101
Bariumμg/l10Sampled Jun 2025≤ 1,00010
Ironμg/l10Sampled Jun 2025≤ 20010
Manganeseμg/l10Sampled Jun 2025≤ 5010
Leadμg/lNot reported≤ 10—
Seleniumμg/l2Sampled Jun 2025≤ 102
Sodiummg/l0.9Sampled Jun 2025≤ 2000.9

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled Jun 2025No limit0.005
Total Trihalomethanesμg/l11.2Sampled Jun 2025≤ 1000.56

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Heptachlorug/L0.005Sampled Jun 2025≤ 0.40.005
Total pesticidesug/L0.5 (Near the limit)Sampled Jun 2025≤ 0.50.5

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled Jun 2025≤ 700.02
Atrazineug/L0.005Sampled Jun 2025≤ 30.005

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Jun 2025No limit0.001
PFOSug/L0.001Sampled Jun 2025No limit0.001
PFNAug/L0.001Sampled Jun 2025No limit0.001
Total PFASug/L0.028Sampled Jun 2025≤ 0.10.003
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l5.8No limit5.8

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.