CULMONT · Cohons

VEOLIA EAU

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.430.2 – 10.009
Total Chlorinemg CL2/l0.49No limit0.098

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC9.6No limit9.6
Hardnessmg CaCO3/l29380 – 459293
Hardness fF29.3No limit29.3
pH7.96.5 – 9.57.9
TurbidityNTU0.2≤ 40.02
ColorColor Units5Sampled Dec 2025≤ 155
ConductivityμS / cm560≤ 2,500560
TDSmg/l358.4estimated0 – 1,199358.4
Alkalinitymg CaCO3/l241No limit241

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l10≤ 500.5
Fluoridemg F/l0.05≤ 1.50.015
Mercuryμg Hg/l0.01≤ 10.001
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l29≤ 508.7

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l4.7No limit4.7
Calciummg/l110No limit110
Potassiummg/l0.78No limit0.78
Chloridemg/l18≤ 25018

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l10≤ 20010
Antimonyμg/l0.05≤ 50.05
Arsenicμg/l0.08≤ 100.04
Bariumμg/l10.5≤ 1,00010.5
Cadmiumμg/l0.01≤ 50.01
Chromiumμg/l0.22≤ 500.22
Copperμg/l6.29≤ 2,0000.31
Ironμg/l4≤ 2004
Manganeseμg/l0.11≤ 500.11
Leadμg/l0.3≤ 100.015
Nickelμg/l0.4≤ 200.4
Seleniumμg/l0.5≤ 100.5
Sodiummg/l6.5≤ 2006.5

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1No limit0.005
Total Trihalomethanesμg/l11.4≤ 1000.57

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsμg/l7≤ 600.35

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Total pesticidesug/L0.007≤ 0.50.007

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02≤ 700.02
Atrazineug/L0.005≤ 30.005

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.002No limit0.002
PFOSug/L0.002No limit0.002
PFNAug/L0.002No limit0.002
Total PFASug/L0.005≤ 0.10.001
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.05No limit0.015
Sulfatemg/l15No limit15
Uraniumug/L0.29No limit0.29

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.