ST BONNET AVALOUZE BOURG (LA BORIE) · Chanac-les-Mines
SYNDICAT DES DEUX VALLEES
Water safety
Water safety
Parameter
Unfiltered tap water
Allowed range
Filtered
Free Chlorinemg CL2/l
0.25Sampled Mar 2026
0.2 – 1
0.005 ▲
Total Chlorinemg CL2/l
0.3Sampled Mar 2026
No limit
0.06
General
General
Parameter
Unfiltered tap water
Allowed range
Filtered
TemperatureC
16.5
No limit
16.5
Hardnessmg CaCO3/l
91
80 – 459
91
Hardness fF
9.1
No limit
9.1
pH
7.3
6.5 – 9.5
7.3
TurbidityNTU
0.3
≤ 4
0.03
ColorColor Units
5
≤ 15
5
ConductivityμS / cm
254
≤ 2,500
254
TDSmg/l
162.6estimated
0 – 1,199
162.6
Alkalinitymg CaCO3/l
79
No limit
79
Pathogens
Pathogens
Parameter
Unfiltered tap water
Allowed range
Filtered
ClostridiumUFC/100ml
0
≤ 0
0
eColiUFC/100ml
0
≤ 0
0
BacteriasNMP/100ml
0
≤ 0
0
EnterococcusUFC/100ml
0
≤ 0
0
Chemical parameters
Chemical parameters
Parameter
Unfiltered tap water
Allowed range
Filtered
Mercuryμg Hg/l
Not reported
≤ 1
—
Nitritesmg NO2/l
0.01
≤ 0.5
0.004
Nitratesmg NO3/l
5.3
≤ 50
1.59
Minerals
Minerals
Parameter
Unfiltered tap water
Allowed range
Filtered
Chloridemg/l
25
≤ 250
25
Metals
Metals
Parameter
Unfiltered tap water
Allowed range
Filtered
Arsenicμg/l
0.3
≤ 10
0.15
Ironμg/l
2
≤ 200
2
Leadμg/l
Not reported
≤ 10
—
Perfluorinated chemicals
Perfluorinated chemicals
Parameter
Unfiltered tap water
Allowed range
Filtered
PFOAug/L
0.001Sampled Jun 2025
No limit
0.001
PFOSug/L
0.001Sampled Jun 2025
No limit
0.001
PFNAug/L
0.001Sampled Jun 2025
No limit
0.001
Total PFASug/L
0Sampled Jun 2025
≤ 0.1
0
PFAS 4ng/l
Not reported
No limit
—
PFAS 21ng/l
Not reported
No limit
—
Other
Other
Parameter
Unfiltered tap water
Allowed range
Filtered
Ammoniamg/l
0.01
No limit
0.003
Sulfatemg/l
2.7
No limit
2.7
Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.