PALLUAU SUR INDRE · Buzançais

SIAEP CLION SUR INDRE

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.07 (Near the limit)0.2 – 10.001
Total Chlorinemg CL2/l0.13No limit0.026

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC25.6No limit25.6
Hardnessmg CaCO3/l30680 – 459306
Hardness fF30.6No limit30.6
pH7.36.5 – 9.57.3
TurbidityNTU0.3≤ 40.03
ColorColor Units5≤ 155
ConductivityμS / cm697Sampled Dec 2025≤ 2,500697
TDSmg/l446.1Sampled Dec 2025estimated0 – 1,199446.1
Alkalinitymg CaCO3/l273No limit273
Bicarbonatemg HCO3/l356Sampled Oct 2025No limit356

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l5Sampled Oct 2025≤ 500.25
Fluoridemg F/l0.1Sampled Oct 2025≤ 1.50.03
Mercuryμg Hg/l0.015Sampled Oct 2025≤ 10.002
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l52 (Near the limit)≤ 5015.6

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l2.1Sampled Oct 2025No limit2.1
Calciummg/l118Sampled Oct 2025No limit118
Potassiummg/l1.5Sampled Oct 2025No limit1.5
Chloridemg/l20.9≤ 25020.9

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l2Sampled Oct 2025≤ 2002
Antimonyμg/l0.2Sampled Feb 2025≤ 50.2
Arsenicμg/l0.8Sampled Oct 2025≤ 100.4
Bariumμg/l5Sampled Oct 2025≤ 1,0005
Cadmiumμg/l0.01Sampled Feb 2025≤ 50.01
Chromiumμg/l0.5Sampled Feb 2025≤ 500.5
Ironμg/l2≤ 2002
Manganeseμg/l1Sampled Oct 2025≤ 501
Leadμg/lNot reported≤ 10—
Sodiummg/l8.5Sampled Oct 2025≤ 2008.5

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled Oct 2025No limit0.005

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Heptachlorug/L0.001Sampled Oct 2025≤ 0.40.001
Total pesticidesug/L0.073Sampled Oct 2025≤ 0.50.073

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled Oct 2025≤ 700.02
Atrazineug/L0.01Sampled Oct 2025≤ 30.01

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Oct 2025No limit0.001
PFOSug/L0.002Sampled Oct 2025No limit0.002
PFNAug/L0.001Sampled Oct 2025No limit0.001
Total PFASug/L0.001Sampled Oct 2025≤ 0.10
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l23No limit23

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.