Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

GRAND POITIERS BERUGES · Ayron

EAUX DE VIENNE - SIVEER

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.30.2 – 10.006
Total Chlorinemg CL2/l0.3No limit0.06

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC26No limit26
Hardnessmg CaCO3/l28080 – 459280
Hardness fF28No limit28
pH7.66.5 – 9.57.6
TurbidityNTU0.3≤ 40.03
ConductivityμS / cm648≤ 2,500648
TDSmg/l414.7estimated0 – 1,199414.7
Alkalinitymg CaCO3/l231No limit231

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Fluoridemg F/l1.4 (Near the limit)≤ 1.50.42
Mercuryμg Hg/lNot reported≤ 1—
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l22≤ 506.6

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Chloridemg/l32≤ 25032

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Antimonyμg/l0.5Sampled Oct 2025≤ 50.5
Arsenicμg/lNot reported≤ 10—
Cadmiumμg/l0.025Sampled Oct 2025≤ 50.025
Chromiumμg/l1Sampled Oct 2025≤ 501
Copperμg/l20Sampled Oct 2025≤ 2,0001
Ironμg/l45≤ 20045
Leadμg/l0.4Sampled Oct 2025≤ 100.02
Nickelμg/l1Sampled Oct 2025≤ 201

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Total Trihalomethanesμg/l7.85Sampled Oct 2025≤ 1000.39

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
Total PFASug/LNot reported≤ 0.1—
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l44No limit44

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.