Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

ERCHIN · Aniche

SIDEN-SIAN NOREADE PECQUENCOURT

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.260.2 – 10.005
Total Chlorinemg CL2/l0.32No limit0.064

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC19.2No limit19.2
Hardnessmg CaCO3/l384.380 – 459384.3
Hardness fF38.4No limit38.4
pH7.16.5 – 9.57.1
TurbidityNTU0.15≤ 40.015
ColorColor Units5≤ 155
ConductivityμS / cm843≤ 2,500843
TDSmg/l539.5estimated0 – 1,199539.5
Alkalinitymg CaCO3/l378No limit378
Bicarbonatemg HCO3/l461No limit461

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalμg CN/l10Sampled Feb 2026≤ 500.5
Fluoridemg F/l0.22Sampled Feb 2026≤ 1.50.066
Mercuryμg Hg/l0.01Sampled Feb 2026≤ 10.001
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l9.3≤ 502.79

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/l16.5Sampled Feb 2026No limit16.5
Calciummg/l133.1Sampled Feb 2026No limit133.1
Potassiummg/l3Sampled Feb 2026No limit3
Chloridemg/l36≤ 25036

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumμg/l10Sampled Feb 2026≤ 20010
Antimonyμg/l1Sampled Feb 2026≤ 51
Arsenicμg/l2Sampled Feb 2026≤ 101
Bariumμg/l67Sampled Feb 2026≤ 1,00067
Cadmiumμg/l1Sampled Feb 2026≤ 51
Chromiumμg/l5Sampled Feb 2026≤ 505
Copperμg/l16Sampled Feb 2026≤ 2,0000.8
Ironμg/l46Sampled Feb 2026≤ 20046
Manganeseμg/l10Sampled Feb 2026≤ 5010
Leadμg/l2Sampled Feb 2026≤ 100.1
Nickelμg/l5Sampled Feb 2026≤ 205
Seleniumμg/l2Sampled Feb 2026≤ 102
Sodiummg/l19.4Sampled Feb 2026≤ 20019.4

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Trichloroethyleneμg/l0.1Sampled Feb 2026No limit0.005
Total Trihalomethanesμg/l9.51Sampled Feb 2026≤ 1000.48

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsμg/l2.4Sampled Feb 2026≤ 600.12

Pesticides

Pesticides
ParameterUnfiltered tap waterAllowed rangeFiltered
Total pesticidesug/L0.2Sampled Feb 2026≤ 0.50.2

Herbicides

Herbicides
ParameterUnfiltered tap waterAllowed rangeFiltered
D 2 4ug/L0.02Sampled Feb 2026≤ 700.02
Atrazineug/L0.005Sampled Feb 2026≤ 30.005

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAug/L0.001Sampled Feb 2026No limit0.001
PFOSug/L0.001Sampled Feb 2026No limit0.001
PFNAug/L0.001Sampled Feb 2026No limit0.001
Total PFASug/L0.001Sampled Feb 2026≤ 0.10
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Perchlorateug/L0.91Sampled Mar 2026No limit0.91
Sulfatemg/l55No limit55
Uraniumug/L10Sampled Feb 2026No limit10

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.