Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg CL2/l0.17 (Near the limit)0.2 – 10.003
Total Chlorinemg CL2/l0.27No limit0.054

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
TemperatureC26.5No limit26.5
Hardnessmg CaCO3/l22480 – 459224
Hardness fF22.4No limit22.4
pH7.76.5 – 9.57.7
TurbidityNTU0.3≤ 40.03
ColorColor Units5≤ 155
ConductivityμS / cm535≤ 2,500535
TDSmg/l342.4estimated0 – 1,199342.4
Alkalinitymg CaCO3/l180No limit180

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100ml0≤ 00
eColiUFC/100ml0≤ 00
BacteriasNMP/100ml0≤ 00
EnterococcusUFC/100ml0≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Mercuryμg Hg/lNot reported≤ 1—
Nitritesmg NO2/l0.01≤ 0.50.004
Nitratesmg NO3/l1.2≤ 500.36

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Chloridemg/l30.7≤ 25030.7

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Antimonyμg/l0.2Sampled Jul 2025≤ 50.2
Arsenicμg/lNot reported≤ 10—
Cadmiumμg/l0.01Sampled Jul 2025≤ 50.01
Chromiumμg/l0.4Sampled Jul 2025≤ 500.4
Copperμg/l11Sampled Jun 2026≤ 2,0000.55
Ironμg/l1≤ 2001
Manganeseμg/l0.9≤ 500.9
Leadμg/l7.6Sampled Jun 2026≤ 100.38
Nickelμg/l4.3Sampled Jun 2026≤ 204.3

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Total Trihalomethanesμg/l33≤ 1001.65

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsμg/l4.4Sampled Apr 2026≤ 600.22

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
Total PFASug/LNot reported≤ 0.1—
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/l0.01No limit0.003
Sulfatemg/l52.5No limit52.5

Data from the French health inspection of drinking water (Ministry of Health, regional health agencies), per distribution unit. Quality ranges are based on WHO guidelines, EU Directive 2020/2184 and the French public health code.