← Back to summarySee all parameters
RED AJANEDO · Miera
AYTO. DE SOBA
Water safety
Water safety| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Free Chlorinemg/L | 0.2 | 0.2 – 1 | 0.004 ▲ |
|---|
General
General| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Hardnessmg CaCO3/l | Not reported | 80 – 459 | — |
|---|
| pHUnidades pH | 7.8 | 6.5 – 9.5 | 7.8 |
|---|
| TurbidityUNF | 0.6 | ≤ 4 | 0.06 |
|---|
| Colormg Pt-Co/L | 1 | ≤ 15 | 1 |
|---|
| ConductivityµS/cm a 20ºC | 229 | ≤ 2,500 | 229 |
|---|
| TDSmg/l | 146.6estimated | 0 – 1,199 | 146.6 |
|---|
| OdorIn. Dil. | 0 | ≤ 3 | 0 |
|---|
Pathogens
Pathogens| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| eColiUFC/100 ml | 0 | ≤ 0 | 0 |
|---|
| BacteriasUFC/100 ml | 0 | ≤ 0 | 0 |
|---|
| EnterococcusUFC/100 ml | 0 | ≤ 0 | 0 |
|---|
Chemical parameters
Chemical parameters| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Fluoridemg/L | 0.1Sampled Feb 2022 | ≤ 1.5 | 0.03 |
|---|
| Mercuryμg Hg/l | Not reported | ≤ 1 | — |
|---|
| Nitritesmg/L | 0.03Sampled Feb 2022 | ≤ 0.1 | 0.012 |
|---|
| Nitratesmg/L | 4Sampled Feb 2022 | ≤ 50 | 1.2 |
|---|
Minerals
Minerals| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Chloridemg/L | 7Sampled Feb 2022 | ≤ 250 | 7 |
|---|
Metals
Metals| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Arsenicμg/l | Not reported | ≤ 10 | — |
|---|
| Chromiumµg/L | 5Sampled Apr 2024 | ≤ 50 | 5 |
|---|
| Coppermg/L | 200Sampled Apr 2024 | ≤ 2,000 | 10 |
|---|
| Ironµg/L | 21Sampled Apr 2024 | ≤ 200 | 21 |
|---|
| Leadµg/L | 1.5Sampled Apr 2024 | ≤ 10 | 0.075 |
|---|
| Nickelµg/L | 2Sampled Apr 2024 | ≤ 20 | 2 |
|---|
Perfluorinated chemicals
Perfluorinated chemicals| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Total PFASug/L | Not reported | ≤ 0.1 | — |
|---|
| PFAS 4ng/l | Not reported | No limit | — |
|---|
| PFAS 21ng/l | Not reported | No limit | — |
|---|
Other
Other| Parameter | Unfiltered tap water | Allowed range | Filtered |
|---|
| Ammoniamg/L | 0.15Sampled Feb 2022 | No limit | 0.045 |
|---|
| Sulfatemg/L | 7Sampled Feb 2022 | No limit | 7 |
|---|
Data collected from the water supplier for your area. Quality ranges are based on WHO, EU and Spanish guidelines.