Skip to content
Filter your tap water with TAPP Water
TappwaterYour Water Quality
← Back to summary

See all parameters

RED MUNICIPAL DE VILLASDARDO · Cipérez

AYTO. DE VILLASDARDO

Water safety

Water safety
ParameterUnfiltered tap waterAllowed rangeFiltered
Free Chlorinemg/L0.30.2 – 10.006
Chloraminemg/L0Sampled Jul 2025≤ 40

General

General
ParameterUnfiltered tap waterAllowed rangeFiltered
Hardnessmg/L55 (Near the limit)Sampled Mar 202680 – 45955
pHUnidades pH8.1Sampled May 20266.5 – 9.58.1
TurbidityUNF0.3≤ 40.03
Colormg Pt-Co/L0Sampled May 2026≤ 150
ConductivityµS/cm a 20ºCNot reported≤ 2,500—
TDSmg/lNot reported0 – 1,199—
OdorIn. Dil.0Sampled May 2026≤ 30
LSIUnidades pH-0.5Sampled Jul 2025No limit-0.5
Oxidationmg O2 /L1.7Sampled Jul 2025≤ 51.7

Pathogens

Pathogens
ParameterUnfiltered tap waterAllowed rangeFiltered
ClostridiumUFC/100 ml0Sampled Jul 2025≤ 00
eColiUFC/100 ml0Sampled May 2026≤ 00
BacteriasUFC/100 ml0Sampled May 2026≤ 00
EnterococcusUFC/100 ml0Sampled May 2026≤ 00

Chemical parameters

Chemical parameters
ParameterUnfiltered tap waterAllowed rangeFiltered
Cyanide totalµg/L0Sampled Jul 2025≤ 500
Fluoridemg/L0Sampled Jul 2025≤ 1.50
Mercuryµg/L0Sampled Jul 2025≤ 10
Nitritesmg/L0Sampled Jul 2025≤ 0.10
Nitratesmg/L0Sampled Jul 2025≤ 500

Minerals

Minerals
ParameterUnfiltered tap waterAllowed rangeFiltered
Magnesiummg/L4Sampled Mar 2026No limit4
Calciummg/L15Sampled Mar 2026No limit15
Potassiummg/L2Sampled Mar 2026No limit2
Chloridemg/L23Sampled Jul 2025≤ 25023

Metals

Metals
ParameterUnfiltered tap waterAllowed rangeFiltered
Aluminiumµg/L59Sampled Jul 2025≤ 20059
Antimonyµg/L0Sampled Jul 2025≤ 50
Arsenicµg/L2Sampled Jul 2025≤ 101
Cadmiumµg/L0Sampled Jul 2025≤ 50
Chromiumµg/L0Sampled Jul 2025≤ 500
Coppermg/L0Sampled Jul 2025≤ 2,0000
Ironµg/L0Sampled Jul 2025≤ 2000
Manganeseµg/L0Sampled Jul 2025≤ 500
Leadµg/L0Sampled Jul 2025≤ 100
Nickelµg/L0Sampled Jul 2025≤ 200
Seleniumµg/L0Sampled Jul 2025≤ 100
Sodiummg/L15Sampled Jul 2025≤ 20015

Chlorine by-products

Chlorine by-products
ParameterUnfiltered tap waterAllowed rangeFiltered
Total Trichloroethyleneµg/L0Sampled Jul 2025≤ 100
Trichloroethyleneµg/L0Sampled Jul 2025No limit0
Tetrachloroethyleneµg/L0Sampled Jul 2025No limit0
Total Trihalomethanesµg/L18Sampled Jul 2025≤ 1000.9

Haloacetic acids

Haloacetic acids
ParameterUnfiltered tap waterAllowed rangeFiltered
Total haloacetic acidsµg/L0Sampled Jul 2025≤ 600

Perfluorinated chemicals

Perfluorinated chemicals
ParameterUnfiltered tap waterAllowed rangeFiltered
PFOAµg/L0Sampled Jul 2025No limit0
PFOSµg/L0Sampled Jul 2025No limit0
PFNAµg/L0Sampled Jul 2025No limit0
Total PFASug/LNot reported≤ 0.1—
PFAS 4ng/lNot reportedNo limit—
PFAS 21ng/lNot reportedNo limit—

Other

Other
ParameterUnfiltered tap waterAllowed rangeFiltered
Ammoniamg/L0Sampled Jul 2025No limit0
Sulfatemg/L0Sampled Jul 2025No limit0
Uraniumµg/L0Sampled Jul 2025No limit0

Data collected from the water supplier for your area. Quality ranges are based on WHO, EU and Spanish guidelines.